Canon Error Code 2

E013
•The PLL lock is released because waste toner motor is locked up,etc.
•The micro switch employed to detect clogging of waste toner is activated.
•The waste toner case is detected full.
E014
•The PLL lock of the fixing/feeding motor is released.
•Excess current of the feeding motor is detected.
E015
•Clock pulses of the pick-up/duplexing/developing motor fails to be generated or
be detected.
•Excess current of the pick-up/duplexing/developing motor is detected.
E016 Excess current of the reciprocating motor
of the photosensitive drum cleaner unit is detected.
E017 The PLL lock of the drive motor of the holding tray unit is released.
E018 The PLL lock of the drive motor of the oil removing roller is
E019 The waste toner case is detected full although it is not.
E020 The developer fails to be replenished with starter developer properly.
Read More..

Canon Error Code

E051 The home position of the side registration cannot be detected

within a specific time.

E054 The home position of the duplexing unit feed roller cannot bedetected.

E055 The horizontal registration guide of the duplex unit exceeds its

maximum travel distance.

E060 The home position of the primary corona wire cleaner cannot be

detected within a specific time.

Relateted charging

E061 Specific potential is not be required or the limiter is activated as the

potential is controlled.

E062 The photosensitive drum temperature does not reach a specific

value due to a fault in the photosensitive drum heater, etc.

E063

The home position of the transfer corona wire cleaner cannot be

detected.

An error code is

not to be

indicated.

E064 The setting value for the output from the microcomputer

considerably deviates from the control value of the actual output.

E065 High voltage leakage from the primary corona assembly is

detected.

E066 Signals from the temperature/humidity sensor cannot be detected.

E067

Two or more faults in the primary/ pre (post)-transfer/ transfer/

separation high voltage are detected (including power output

stoppage, electric leakage from the primary corona assembly).

E068 High voltage leakage from or an open circuit in the separation

corona assembly is detected.

E069 High voltage leakage from or an open circuit in the transfer corona

assembly is detected.

E070 The home position of the transfer drum cannot be detected within a specific time.

E071 An image leading edge signal cannot be detected within a specifictime.

E072 A fault in the main motors such as the transfer drum motor, etc.